CVE-2025-30046
CRITICAL
INFO
Priority: 0.02
BB Relevance:
63/100
Published: 2026-10-23
Modified: 2026-10-28
First seen: 2026-10-29
Status: active
Attack Surface
Adjacent
Low Complexity
No Auth
No Interaction
Conf. Impact
Integ. Impact
CVSS Vector Breakdown
AV:
Adjacent
AC:
Low
PR:
None
UI:
None
AT:
Present
VC:
High
VI:
High
VA:
High
Description
In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges. The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.
Weakness Classification (1)
Affected Software (2)
| Vendor | Product | Version |
|---|---|---|
| CGM | CGM CLININET | 0 |
| CGM | CGM CLININET | 0 |